{"product_id":"solaredge-optimizer-p860","title":"SolarEdge, Optimizer, P860","description":"\u003cdiv class=\"col_right\"\u003e\n\u003cp\u003e\u003cem\u003eSeries 5 - MC4 Compatible Input Connectors, MC4 Compatible Output Connectors, For parallel connection of two landscape mounted PV modules up to 860 watts, 1000 Max Vdc\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e2:1 Optimizer, 860W\/120V - Commercial Inverters only - 208V\/480V\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNote\u003c\/b\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eIt is not allowed to mix S-series and P-series Power Optimizers in new installations.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eOne optimizer per 2 modules with SolarEdge StorEdge Inverter. Mitigates effects from manufacturing tolerance, partial shading \u0026amp; orientation. Flexible system design for maximum space utilization. Fast installation with single bolt.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"pv_specs\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP860-2XLONG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSeries 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSolarEdge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eMechanical\u003c\/h2\u003e\n\u003ctable class=\"pv_specs\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eCommercial Power Optimizer\u003cbr\u003e(for 2 x 72 cell PV modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40° C to +85° C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible SolarEdge Inverters\u003c\/td\u003e\n\u003ctd\u003eThree phase inverters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power per String\u003c\/td\u003e\n\u003ctd\u003e6000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Strings of Different Lengths or Orientations\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP68 \/ NEMA6P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e5\" x 5.97\" x 2.32\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.34 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Method\u003c\/td\u003e\n\u003ctd\u003eGround\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInput (DC)\u003c\/h2\u003e\n\u003ctable class=\"pv_specs\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Power\u003c\/td\u003e\n\u003ctd\u003e860 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Input Voltage\u003cbr\u003e(Voc at lowest temperature)\u003c\/td\u003e\n\u003ctd\u003e60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Operating Range\u003c\/td\u003e\n\u003ctd\u003e12.5 - 60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Short Circuit Current (Isc)\u003c\/td\u003e\n\u003ctd\u003e22 ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Short Circuit Current per Input (Isc)\u003c\/td\u003e\n\u003ctd\u003e11 ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Efficiency\u003c\/td\u003e\n\u003ctd\u003e99.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeighted Efficiency\u003c\/td\u003e\n\u003ctd\u003e98.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eOutput (DC)\u003c\/h2\u003e\n\u003ctable class=\"pv_specs\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current - During Operation\u003c\/td\u003e\n\u003ctd\u003e18 ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Voltage\u003c\/td\u003e\n\u003ctd\u003e80 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe SolarEdge power optimizer is a DC\/DC converter which is connected by installers to each PV module or embedded by module manufacturers, replacing the traditional solar junction box. The SolarEdge power optimizers increase energy output from PV systems by constantly tracking the maximum power point (MPPT) of each module individually. Furthermore, the power optimizers monitor the performance of each module and communicate performance data to the SolarEdge monitoring portal for enhanced, cost-effective module-level maintenance. Each power optimizer is equipped with the unique SafeDC™ feature which is designed to automatically shut down modules' DC voltage whenever the inverter or grid power is shut down (unless connected to a StorEdge Inverter that is in backup mode).\u003c\/p\u003e\n\u003cp\u003eThe MPPT per module allows for flexible installation design with multiple orientations, tilts and module types in the same string. When working with SolarEdge Inverters, SolarEdge power optimizers automatically maintain a fixed string voltage, allowing installers even greater flexibility with longer strings and strings of different lengths in order to design optimal PV systems. The SolarEdge power optimizers are compatible with c-Si and thin-film modules and have a 25 year warranty.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSpecifically designed to work with SolarEdge inverters\u003c\/li\u003e\n\u003cli\u003eUp to 25% more energy\u003c\/li\u003e\n\u003cli\u003eSuperior efficiency (99.5%)\u003c\/li\u003e\n\u003cli\u003eBalance of System cost reduction; 50% less cables, fuses and combiner boxes, over 2x longer string lengths possible\u003c\/li\u003e\n\u003cli\u003eFast installation with a single bolt\u003c\/li\u003e\n\u003cli\u003eAdvanced maintenance with module-level monitoring\u003c\/li\u003e\n\u003cli\u003eModule-level voltage shutdown for installer and firefighter safety\u003c\/li\u003e\n\u003cli\u003eUse with two PV modules connected in series or in parallel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Legacy Solar Parts","offers":[{"title":"Default Title","offer_id":51853761282264,"sku":"WILL","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0737\/0480\/0472\/files\/Screenshot2026-06-19175940.png?v=1781906398","url":"https:\/\/legacysolarparts.com\/products\/solaredge-optimizer-p860","provider":"Legacy Solar Parts","version":"1.0","type":"link"}